MM-EM08-012
Magnetic incremental feedback, 12 ppr on 2 channels, TTL compatible.
- Class
- Magnetic incremental
- Lifecycle
- active
- Revision
- A
- Review
- Verified record
- Sample
- Quoted with the configuration
- Lead time
- Quoted with the configuration
- Verified
- 2026-08-18
Envelope and model
- Model bounding box, X × Y × Z
- 7.8 mm × 7.8 mm × 11.0 mm
- Model revision
- A, reviewed 2026-08-18
- Mesh
- 172 triangles
Reviewed specifications
Supply, signal, resolution and limits.
| Specification | Value | Basis | Note |
|---|---|---|---|
| Encoder type | Incremental | Published | |
| Sensing element | Magnetoresistive effect element | Published | |
| Envelope diameter | 8mm | Published | |
| Resolution | 12ppr | Published | |
| Channels | 2 | Published | |
| Output signal | TTL compatible | Published | |
| Supply voltage | 5.0V | Published | |
| Supply tolerance | 5% | Published | |
| Supply current, maximum | 20mA | Maximum | |
| Output current, maximum | 3mA | Maximum | |
| Maximum frequency | 20kHz | Maximum | |
| Operating temperature, minimum | -10°C | Published | |
| Operating temperature, maximum | 60°C | Published | |
| Cable | AWG28 flat band cable | Published | |
| Index channel | Not published | Not established | Ask for it in a fit review. |
The frequency limit sets the top speed.
Not the resolution. Counts per revolution and the output frequency limit together fix the shaft speed this feedback can follow.
n_max = f_max ÷ P × 60 = 20,000 Hz ÷ 12 ppr × 60 = 100,000 rpm
- n_max
- shaft speed at which one channel reaches the frequency limit
- f_max
- maximum output frequency, 20 kHz, a published maximum
- P
- pulses per revolution
Compatible parts
Application fit and cautions
Read out of this record's own numbers.
Documents, models and next steps
Free and ungated
This specification record is free to read, index and quote, with no form in front of it. You should not have to trade personal data for enough information to reject a product.
A sanitized browser model (GLB, revision A, reviewed 2026-08-18) is published for this envelope: Download the GLB model
Not published yet
A 2D PDF drawing, a DXF and a neutral STEP file are not published for this record today, so there is no link here to a file that does not exist. A configured drawing carries tolerances and interface dimensions we will stand behind, which is why it comes out of a short qualified request rather than a download button.
Record MM-EM08-012, revision A, verified by Micro Motion application engineering on 2026-08-18. Catalog 2026-08-18.public.1.